Notify me when the price drops
We will email you if we find a lower price on this product!
SMX3000XLRT2U (SM8807)
Intelligent, line interactive rack/tower uninterruptible power supply
§ 3kVA / 3000VA / 2250W line interactive 2Urack/tower UPS; Sine wave output
§ 230V nominal output during brownouts to 158Vand over voltages to 278V
§ Add optional WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature
§ Extended runtime options up to 1600W
§ Detailed status LEDs; 3 switched output load banks
§ C20 inlet; 8 C13 & 1 C19 outlets; Includes 3 C13 to C14 cables
Overview
Tripp Lite's SMX3000XLRT2U intelligent, line interactive rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. Requires only two rack spaces (2U) in a standard rack enclosure. Large internal batteries offer 10 minutes half load runtime and 3.3 minutes at full load. Runtime is expandable with optional BP48V24-2U or BP48V60RT-3U external battery packs. Maintains regulated 230V nominal output without using battery power during brownouts and over voltages from 158 to 278V. 3000VA/2250-wattpower handling capability and full-time since wave output offers guaranteed compatibility with networking, telecom and other sensitive electronic applications. Includes a total of 9 outlets with 3 load banks that are individually switchable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment. Supports simultaneous remote monitoring of UPS and site power conditions via built-in USB and DB9 monitoring ports. Includes Power Alert UPS monitoring and unattended shutdown software with complete cabling. Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD and RELAYIOCARD. Emergency Power Off (EPO) interface offers option for instantaneous power-off of UPS and connected equipment in the case of fire or emergency. Multi-function audible alarms and set of 5 front panel LEDs offer at-a-glance notification of UPS and line power status. Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise. Attractive all-black color scheme.
Features
§ SMX3000XLRT2U line interactive UPS offers battery derived sine wave AC output during power outages, voltage regulation during brownouts and over voltages, plus network-grade AC surge suppression
§ 3000VA/2250-watt power handling capability with full-time sine wave output offers guaranteed compatibility with networking, telecom and other sensitive electronic devices
§ Supports 2U rackmount installation in 4 post equipment racks, 2 post rackmount installation requires 2POSTRMKITWM, upright tower installation requires 2-9USTAND accessory
§ Large internal batteries support a half load of 1500VA for 10 minutes and a full load of 3000VA for 3.3 minutes
§ Runtime is further expandable with the addition of external battery packs BP48V24-2U (limit 1), BP48V60RT-3U(multi-pack compatible) and BP48V27-2US (multi-pack compatible)
§ Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
§ Intelligent battery management system extends battery life
§ Maintains regulated 230V nominal output during brownouts and over voltages from 158 to 278V
§ Includes 9 UPS supported outlets arranged in3 individually controllable load banks (2 outlets per bank) that can be powered off and back on again via software interface
§ IEC320-C20 input connection accepts a variety of detachable cord sets to match country or site-specific wall receptacles
§ Power Alert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user-defined script commands.
§ Offers simultaneous monitoring through included USB and DB9 interface ports, or the monitoring by any number of additional servers over IP with included Power Alert monitoring software.
§ Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored AC line voltage, DC battery voltage and remaining battery capacity
§ Emergency Power Off (EPO) interface withcable
§ Supports timed inverter shutoff afterunattended shutdown, activate self-test and UPS output power control fordelayed or immediate reboot of connected devices
§ Supports Tripp Lite's WatchDog softwareapplication to restore operation to locked equipment through soft reboot ofapplication, OS or hard power off/on reboot of connected equipment - ideal forunattended kiosk applications (requires optional WATCHDOGSW)
§ Built-in accessory slot supports SNMP withoptional SNMPWEBCARD adapter
§ Optional WEBCARDLX (sold separately) withthe latest version of PowerAlert Device Manager firmware (PADM20) providesenhanced remote management capabilities
§ PADM20 and PowerAlert Element Manager (PAEM)form a powerful tool for expanding maintenance functions in largeinstallations, including firmware update checks and backup and restoration ofdevice configurations
§ IP-based Auto Probe detects lostconnectivity and restores service autonomously
§ Emergency Power Off (EPO) interface withcable
§ Multi-function audible alarms and set of 5front panel LEDs
§ Network-grade AC surge suppression
§ Attractive all-black color scheme
§ Optional PDUBHV20 bypass PDU enableshot-swappable UPS replacement with no disruption to connected equipment
§ UPS battery set ships fully assembled, notime consuming connection of internal batteries by user is necessary
PackageIncludes
§ SMX3000XLRT2U UPS System
§ PowerAlert software with USB and DB9 cables
§ Mounting hardware for 4 post rackmountapplications
§ Cable for Emergency Power Off interface
§ Instruction manual with warranty information
Specifications
OVERVIEW
UPC Code
037332120502
UPS Type
Line-Interactive
INPUT
Rated input current (Maximum Load)
15A
Nominal Input Voltage(s) Supported
230V AC
UPS Input Connection Type
C20 inlet
UPS Input Connection Description
User supplies input cabling with C19 output connection
Input Circuit Breakers
20A
Input Phase
Single-Phase
OUTPUT
Output Volt Amp Capacity (VA)
3000
Output Capacity (kVA)
3
Output Watt Capacity (Watts)
2250
Output kW Capacity (kW)
2.25
Output Capacity Details
Output is reduced to 1600W maximum when used with external battery packs
Power Factor
0.75
Nominal Voltage Details
230v nominal inverter output voltage
Frequency Compatibility
50 / 60 Hz
Frequency Compatibility Details
Automatic frequency selection
Output Voltage Regulation (Line Mode)
230V (-15%, +6% )
Output Voltage Regulation (Battery Mode)
+/- 5%
Included Output Power Cables
Includes 3 C13 to C14 output power cables
Load Management Receptacles
Three switchable two-outlet C13 load banks
Output Circuit Breakers
10A (x2) - each breaker protects 4 C13 outlets, C19 outlet does not include a breaker
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery Mode)
Pure Sine wave
Nominal Output Voltage(s) Supported
230V
Output Receptacles
(8) C13; (1) C19
Individually Controllable Load Banks
Yes
BATTERY
Battery Type
Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.)
3.35 min. (2250w)
Half Load Runtime (min.)
10 min. (1125w)
Expandable Battery Runtime
Extended runtime supported via optional external battery packs
Expandable Runtime
Yes
External Battery Pack Compatibility
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
DC System Voltage (VDC)
48
Battery Recharge Rate (Included Batteries)
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
Battery Access
Front panel battery access door
Internal UPS Replacement Battery Cartridge
RBC94-2U
Battery Replacement Description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278
Overvoltage Correction
Input voltages between 244 and 278 are reduced by 12%
Undervoltage Correction
Input voltages between 182 and 206 are boosted by 12%
Severe Undervoltage Correction
Input voltages between 158 and 182 are boosted by 24%
USER INTERFACE, ALERTS & CONTROLS
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation; Rear dip-switch for charger rate adjustment
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm
Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
480
UPS AC Suppression Response Time
Instantaneous
EMI / RFI AC Noise Suppression
Yes
PHYSICAL
Primary Form Factor
Rackmount
Rack Height
2U
Cooling Method
Fan
Included Mounting Accessory Description
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories
4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories
2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth with External Battery Pack (cm)
66
Minimum Required Rack Depth with External Battery Pack (in.)
26
Minimum Required Rack Depth without External Battery Pack (cm)
57
Minimum Required Rack Depth without External Battery Pack (in.)
22.5
Optional Mounting Accessory Notes
Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary UPS Depth (mm)
483
Primary UPS Height (mm)
89
Primary UPS Width (mm)
445
Shipping Dimensions (hwd / in.)
9.00 x 23.75 x 20.25
Shipping Weight (lbs.)
72.60
UPS Housing Material
Steel
UPS Power Module Dimensions (hwd, in.)
3.5 x 17.5 x 19
UPS Power Module Weight (kg)
29.03
UPS Power Module Weight (lbs.)
64
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
236.6
AC Mode Efficiency Rating (100% Load)
97%
Audible Noise
45 dBA maximum, front side 1m
COMMUNICATIONS
Network Monitoring Port Description
Supports detailed monitoring of UPS and site powe.r conditions; 1 USB port and 1 DB9 serial port.
PowerAlert Software
Included
Communications Cable
USB and DB9 cabling included
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description
Network management card optional
Communications Interface
DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time
4 ms (AC to Battery); 2 ms (Battery to AC) typical
Low Voltage Transfer to Battery Power (Setpoint)
151
High Voltage Transfer to Battery Power (Setpoint)
282
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection
Green Energy-Saving Features
Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Lug
Back panel grounding lug
STANDARDS & COMPLIANCE
Product Compliance
RoHS; CE (Europe); FCC Part 15 Class A (USA)
WARRANTY
Product Warranty Period
Final Sale – As Is no warranty item
shipper pays freight